GLMedia — XR18/MR18: network control, active USB and recovery BLANK TEMPLATE. Checks to perform; not evidence of a system test. INITIAL STATE Console / identifiable revision / firmware: Control app / version / operating system: Current scene saved at / date and state: Recording or playback program / device / project / file path: REMOTE: Ethernet / Wi-Fi Client / Access Point: DHCP Client / DHCP Server / static IP: Console IP / mask / gateway: Router model / LAN port / DHCP enabled / console lease: Control station IP / mask / SSID or LAN port: Alternate wired station / access to the same console checked: ADDRESSES AND LINK DHCP Client requests an address from that network’s server. Console DHCP Server: 192.168.1.1; clients 192.168.1.101–192.168.1.132. Access Point: up to four simultaneous clients. Ethernet without DHCP server: automatic console address within 169.254.1.0–169.254.254.255 according to the cited manuals. A 169.254 address only on the computer does not identify console IP. Actual address at both ends / mask / lease present or absent: Initial cable and port / one variable to change / state to restore: Before / after / new connection / missing information: CONTROL LOST WITH USB ACTIVE Transport state / time / meters / errors / intended listening: Time control was lost / observed recording or playback state: Preserve the active USB path while checking control. Do not restart the console, unplug USB or change sample rate to test networking. Attempt from prepared wired station / identified console / result: Tablet: SSID / local permission / app connected / meters restored: Mixer → PC receives console state; PC → Mixer writes from the computer. Unit / synchronization direction / compared settings / result: REHEARSAL AND FILE Sample recording / planned control change / time of each intervention: Take closed normally / file opened / complete listening: Source | File | Start and end | Discontinuity or silence | Position | Coincident action ______ | ____ | _____________ | ________________________ | ________ | _________________ A running counter does not prove continuous recorded audio. RETURN TO THE PREVIOUS LINK Saved original values / alternate access mode: Corrected parameter / previous value / new value: Connection through alternate mode / configuration read from console: Original REMOTE restored / IP and mask / intended station connected: Correct unit / meters / mix preserved / restoration result: If it fails: last change to check / alternate access restored: Do not assume loading a scene restores network parameters. CONTROL SCOPE XR18: RESET 2 seconds, networking; X AIR V1.0 manual p.14. MR18: RESET 2 seconds, networking; RESET 10 seconds, all factory settings; MR18 guide 24/06/2025 Rev.0, printed page 20. The cited 10-second scope applies to MR18: do not transfer it to XR18. Initialize in Connection, X AIR/M AIR: initializes console and erases settings. Initialize in GUI Preferences, M AIR: clears saved window layout. Exact tab and control / applicable documentation / recovery copy: Pending procedure / model information to confirm / next check: REFERENCES Behringer: X AIR User Manual V1.0, pp.14 and 28: https://cdn-media.empowertribe.com/ffe0de45e14541f797928d639a8933b2/M_BE_0605-AAA_X-AIR_EN.pdf Midas: M AIR MR18/MR12 User Manual, pp.12–13 and 27–28: https://cdn-media.empowertribe.com/f4e89140f9994eed93e4f2a4e086c578/M_MI_0605-AAF_MR18-MR12_EN.pdf Midas: MR18 Quick Start Guide, 24/06/2025 Rev.0, pp.20–23: https://cdn-media.empowertribe.com/3a0cd685a2a4450993e03a09ddb34dc7/QSG_MI_0605-AAF_MR18_WW_2025-06-24_Rev.0.pdf Help: https://glmedia.tech/technical-help/xr18-mr18-router-wifi-control/