MDG theONE

Separate unit enable, emission and output level; read the fluid and gas status before repatching or interrupting the purge.

Ask GLMedia about renting MDG theONE for your event. Availability and configuration are subject to confirmation.

Model and purpose

Manufacturer
MDG Fog Generators
Model
MDG theONE
Configuration
theONE generator; distinguish standalone installation from Touring rack
Power
100–250 VAC, 50/60 Hz; 1100–1480 W
Consumables
MDG Neutral mineral-oil fluid only; industrial CO2 or N2 gas with the specified installation
Control
5 DMX channels; XLR, Ethernet and local keyboard; revision-specific network configuration

An atmospheric generator with fog and haze modes. Fluid and gas are separate consumables, and powered electronics alone do not establish readiness. Confirm that the venue accepts the specified fluid and gas installation before planning the effect.

Prepare your rental inquiry

Specify equipment only or whether setup, programming, operation and strike are also needed. Scope is confirmed in the proposal.

You do not need a final equipment list: tell us the result you want and the part you need help with. Availability and scope are confirmed in the proposal.

Features and connections

The external bottle feeds an internal reservoir. A visible supply of fluid is not proof that the internal level has been restored; the refill pump can run during startup.

DMX/RDM uses 5-pin XLR and network control uses RJ45. Confirm the Pathway board revision, accepted protocol and universe with the network operator. A network reset is not a routine first check; it can remove the existing configuration.

Prepare the system

  1. Record configuration, VERSION, FIRMWARE, communication source, mode and address. Preserve the show and network settings before changes.
  2. Have trained personnel prepare upright secured cylinders, the matching gas regulator and rated lines. Use gas-phase supply, not siphon/liquid CO2, and do not improvise adapters or pressure settings.
  3. Keep generator and fluid container upright, ventilation clear and the test attended. Agree detection, visibility and exhaust with the venue. Wait for READY and compare the intended low-output cue before enabling emission.

Questions and troubleshooting

DMX is present but there is no output, or the keyboard is locked: what should I compare?

Communication selection and emission enables are separate. AUTO gives valid DMX priority over local control.

  1. Read INTERFACE / COMM. LOCAL, DMX and ETHERNET select different sources; compare the actual source before changing the address. For a local test, stop remote commands and agree the handover first.
  2. Compare all channels: 1 UNIT, 2 MODE, 3 OUTPUT, 4 HAZ/FOG and 5 EXT FAN. Raising output alone does not enable the unit or emission. Read the received values and READY state.
  3. Match the complete personality and universe. The documented last starting address is 508; the calculated end is 508 + 5 - 1 = 512. Do not clear a network security domain merely to test a patch.
The external bottle is full but REFILL or a pressure error appears: where do I trace it?

REFILL concerns replenishing the internal reservoir; P. LOW and P. HIGH concern the gas/pressure system. They are different diagnostic paths.

  1. For REFILL, stop emission and inspect the external fluid level, correct vented cap and seated intake line. Compare STATUS / LEVEL with the manual; do not open a pressurized reservoir.
  2. For a pressure error, record STATUS / PRESSURE and the exact error. Have trained personnel check gas type, supply and the specified installation; a full fluid bottle cannot correct an unavailable gas supply.
  3. Stop for a leak, frozen line or recurring fault and use authorized service. Do not defeat a sensor or keep restarting the generator to force it to run.
Can I stop a cue by cutting mains power, or change mode while emitting?

Normal shutdown includes purge and depressurization. A live mode change can also change the visible output immediately.

  1. Stop emission with FOG OFF and keep power available. The cited sequence allows 1 minute for purge plus 30 seconds for reservoir depressurization; verify completion rather than pulling power mid-cycle.
  2. Then select UNIT OFF, switch off mains and close the gas bottles as documented. A remote UNIT OFF also requires complete depressurization before mains is removed.
  3. Rehearse mode changes with the output area clear. HAZE to FOG can produce fog immediately; FOG to HAZE includes an automatic purge. Do not discover that transition near performers.

Quick reference

Read the complete control chain, not just the output fader.
FunctionChannelCheck
Unit enable / mode1 / 2Heating and selected effect
Output / emission3 / 4Level and separate emission gate
External fan5Touring accessory / actual setup

Precautions

Terms on this page

DMX
A data protocol controlling lighting functions; each model defines what its channels mean.
RDM
Management communication for querying or configuring compatible equipment over a compatible path.
Patch
Assignment of fixture, profile, address and universe in the control system.
Personality
A control mode defining the channels and functions used by a fixture.

Documentation and sources

Consulted 2026-10-22. Scope: User Guide B/c, September 2023. Published warm-up and consumption figures vary by edition; actual readiness and the installed revision govern preparation. These are proposed checks without a physical GLMedia test.