Venues · Rigging and LED
Gaylord Rockies, Aurora: rigging plans, loads and services
Gaylord Rockies Resort & Convention Center is at 6700 North Gaylord Rockies Boulevard, Aurora, Colorado. Identify the contracted room and division before planning LED, audio or structures. This informational guide does not establish a booking, an approved design or past GLMedia work.
Which venue and plan apply to the installation?
ID GAYLORD-ROCKIES identifies Aurora, CO, not the Colorado Convention Center in Denver or another Gaylord. Aurora Ballroom and Aurora Exhibit Halls are spaces at this property. Do not transfer Aurora plan values to Adams, Colorado, Juniper, Lodge or Mountain View Pavilion.
Encore’s local page links separate ZIP files by space. The Aurora Exhibit Halls 1–3 and Aurora Ballroom PDFs are included in two ZIPs, and their filenames identify them as 2021. Continued linking alone does not establish the contractual revision or current condition of each point.
What information do the two Aurora plans publish?
The table summarizes the PDFs without treating them as current authorization to use the system. Each plan distinguishes rigging symbols from speakers, lights or other ceiling elements. An installed-system symbol does not establish an available rigging point.
| Item in PDF identified as 2021 | Aurora Exhibit Halls 1–3 | Aurora Ballroom |
|---|---|---|
| Drawn points | 417 | 130 |
| Plan area | 126,542 sq ft | 47,573 sq ft |
| Maximum / minimum ceiling | 25 ft / 13 ft 6 in | 36 ft / 30 ft |
| Published rigging point WLL | 1,000 lb | 1,000 lb |
| Use limit | Approximate plan; revision and loads to confirm | Approximate plan; revision and loads to confirm |
How are loads reviewed, and who handles rigging?
Both plans’ notes require disclosure of all rigged items regardless of weight, verification of point-load calculations and approval of loads by Encore Rigging Services before load-in. They prohibit hanging from airwall tracks and assign hoists and control to Encore. Confirm that scope under the revision applicable to the event.
Prepare complete LED, audio, truss, hoist, cable and accessory weights, locations, point forces and load combinations. The plans describe intermittent show and event use, not permanent support. Mention of chain motors generating dynamic loads does not accept every dynamic effect or replace system calculations.
Do all sources agree on areas and heights?
The Aurora Exhibit Halls 1–3 plan shows a different area from Marriott’s commercial Aurora Exhibition Hall row, which lists 174,115 sq ft and a 30 ft height. Aurora Ballroom agrees at 47,573 sq ft between the plan and Capacity Chart, while another web description uses 59,467 sq ft. The same perimeter or configuration was not confirmed across these figures. The same Capacity Chart also includes a row named Aurora Exhibit Hall 1-3 with 114,648 sq ft and a 30 ft height; confirm its perimeter and revision before comparing it with the plan.
Do not choose the largest figure or add spaces to resolve the difference. Confirm the revision, contracted area and obstructions in the CAD. Maximum ceiling height, minimum height and usable rigging trim height are separate values. Reference occupancy also does not automatically allow for staging, LED and circulation.
What floor and equipment-access information still needs verification?
Confirm allowable floor loads by area, wheel or concentrated support, and freight-elevator or ramp capacities for the project. For a ground-supported LED wall, obtain zone-specific limits and document base reactions, load distribution and the travel route before selecting the system.
Coordinate the assigned dock, appointment, usable door opening, turns, level changes, operator and surface protection. Marriott describes parcel receiving and handling charges; that does not establish a production freight route, dock booking or equipment custody.
What is the scope of AV, power and internet services?
Marriott identifies Encore as an AV partner. Encore’s local page also lists internet, power distribution and rigging. These are service categories, not proof of circuit availability, bandwidth, equipment inventory or overall AV exclusivity. Do not apply wedding-package terms to a convention contract.
| System | Event confirmation required |
|---|---|
| AV and interfaces | Outside-equipment scope, house-system access, patching, operation and staffing. |
| Power | Provider and contractual scope, voltage, phases, connectors, circuits and available power. |
| Internet | Responsible provider, contracted network, capacity, segmentation and connection testing. |
| Rigging | Current CAD, points, forces, hoists and control under plan notes; acceptance before load-in. |
What should be ready before load-in, and which deadlines need confirmation?
The plan notes place load review before load-in, but current deadlines in days for orders, plans or changes must be confirmed with the venue. Do not adopt another Gaylord’s calendar. Prepare load-in, testing, show and load-out schedules, layout revisions and staffing lists to confirm deadlines and coverage.
As a technical recommendation, coordinate RF inventory, bands and concurrent spaces with the local team and check onsite conditions. The current RF list and applicable haze, fog, laser, pyrotechnics or cold sparks policies remain to be confirmed for the event. Submit these effects for review if included in the project.
Which acceptances and permits are needed before finalizing the project?
Before finalizing, obtain the accepted plan, authorized limits and loads, route, services, staffing and confirmed schedule. A provider’s rigging review does not replace hotel acceptance, the contract or permits from the relevant authority.
The organizer coordinates the program, layout and event requirements; each authority decides within its remit. This guide helps prepare the inquiry and track open items. It does not certify engineering, physical operation or approvals.
Frequently asked questions
Can point counts be multiplied by WLL to establish a total load?
No. Drawn quantities and reference WLL do not establish simultaneous or remaining capacity. Individual, combined and system forces require current-plan review and project acceptance.
Does ground-supported LED avoid capacity review?
No. It changes how loads reach the floor. Verify bases, reactions, route, protection and stability to confirm the capacities for this installation.
Are Encore’s ZIPs a general manual for the entire resort?
No. The two reference PDFs cover Aurora spaces and have their own notes. They do not by themselves constitute a current general manual for the resort; other rooms and the contract need specific documentation.
Official documentation
Reviewed October 26, 2026; document cutoff October 18. Official Marriott and Encore sources. Two PDFs identified as 2021 are linked by the local page; contractual validity remains to confirm. Differences between plans, Marriott rows and descriptions require identification of the applicable perimeter and layout; they do not establish approved calculations or an approved installation.