Theater · Loading and technical integration
Moss Center Black Box: loading, grid, audio and lighting
For setup at the Dennis C. Moss Cultural Arts Center Black Box, coordinate the actual room access and adaptation of the installed system. The Main Stage dock does not remove the Black Box door restriction.
Which space, capacity and schedule must be confirmed?
The Black Box is on the east side of the main building at 10950 SW 211 Street, Cutler Bay, Florida 33189, Miami-Dade. It is managed by the Miami-Dade County Department of Cultural Affairs. It is distinct from the Lab Theater and Main Stage: identify the space on plans, services and the contract.
Rental requests require at least 45 days’ notice and contracting at least 30 days. The policy also mentions sending contracts no less than 180 days ahead: obtain a written schedule resolving that difference before fixing setup and ticket sales. A hold lasts 7 days and the public calendar does not show every booking.
Prepare the layout including stage, audience, FOH, cameras, accessible routes and exits. Interior dimensions in the specification are not equipment-free floor area. The venue does not permit rental for private parties and banquets; confirm that the proposed program fits the accepted use.
| Published information | Project limit |
|---|---|
| Room: 48 ft 7 in × 39 ft 4 in, specification 17/07/2026 | Check usable dimensions and north-south / east-west orientation against the setup plan. |
| Space page: maximum 129; technical specification: 136 | Do not select the larger number or treat the smaller one as approval. Obtain written capacity for the specific layout. |
| Fee schedule 23/01/2024: package up to 7 hours | Load-in, performance and load-out fit within that window. Confirm current scope and quotation without assuming additional hours. |
Check the complete package and protect the floor
The specification allows access from the plaza or scheduled use of the Main Stage dock to the west. It lists two 10 ft × 12 ft bays with levelers, but the Black Box doorway is stated as 6 ft high × 6 ft wide. Confirm those dimensions along the actual route before dispatch: measure the case, wheels, handles and assembled equipment, not only the chassis.
Mark doors, turns and holding space without occupying exits. If a package does not fit, redesign packaging or a manufacturer-permitted equipment split; do not improvise tilting or remove building elements. Reschedule delivery if no route is accepted.
The sprung floor uses rubber sleepers, two ¾ in plywood layers and a black Masonite surface. Request allowable concentrated loads, supports and protection for carts, risers and ballast. Screwing or drilling incurs additional charges under the specification; that charge does not authorize the work.
What the grid figure means and what it cannot establish
The grid uses Schedule 40 pipe in 4 ft × 4 ft squares. The specification states 200 lb/ft² and requires prior rigging approval by the Moss Center Production Manager. That figure does not identify allowable load for a point, span or clamp, or residual capacity with installed equipment.
Do not multiply area by that figure to allocate motors, truss or LED. Submit positions, weights, center of gravity, reactions and attachment method; request authorized loads and structural review for the specific proposal. Confirm clearance, obstructions, installed equipment and who may access and work on the grid.
If the proposal is not accepted, remove the suspension or prepare a ground-supported alternative with reviewed loads and circulation. Retain the accepted plan to restore that configuration. A freestanding solution also requires support and stability review.
ETC Ion: reconcile inventory, patch and house restoration
The July 2026 specification identifies ETC Ion and the inventory below. The linked plot dates from 2023: it identifies COLORado 1 Tour while the specification says COLORado Tour 2; COLORado and LoneStar quantities also differ. Check actual model, quantity, mode, address and universe before importing a patch.
Ask the operator for the house file and software version. Check each circuit or fixture with a limited selection and safe level, without changing multiple destinations together. If another fixture responds, review patch and address; if none responds, separate power from DMX signal checks before editing cues.
| Inventory in the 17/07/2026 specification | Quantity |
|---|---|
| ETC Lustr+ Series 1 LED, 19°, logo | 1 |
| ETC Source4, 26° | 1 |
| ETC Source4, 36° | 27 |
| ETC Source4, 50° | 12 |
| ETC Source-Four PAR, MFL / WFL | 14 / 6 |
| Chauvet COLORado Tour 2 LED | 9 |
| LoneStar LED moving light | 8 |
The plot reserves Channel 6, Pipe 12 U#3, as a run light outside design use. Keep it out of show cues until its current role is confirmed. Fixture and power positions are approximate; do not use the plot as an engineering drawing. Rehanging or repositioning may incur additional labor and requires restoration to house positions.
Power, effects and separate approvals
The specification lists 110 V outlets around the room and a 100 A three-phase company switch with cam-loc connections in the lighting/sound booth on the second level. It does not state the voltage of that three-phase supply: do not infer that it matches the outlets. Obtain distribution, voltage, protection, available capacity and authorized connection responsibility before choosing cabling.
The plot places LED breakers in a technical room beside the booth. Coordinate checks with the operator; do not cut power to diagnose DMX or interfere with circuits serving other systems. If the allocation is insufficient, reduce demand or submit another distribution for review.
The fee schedule includes haze and fog rentals, but a price does not authorize an effect. For smoke, haze, lasers or pyrotechnics, identify equipment, manual, position and operation, and obtain venue and competent-authority reviews. Do not alter detection or assume City of Miami permits apply because the venue is in Miami-Dade.
Separate legal permits or authority review, venue technical acceptance, organizer conditions, contract or exclusivities, and technical checks. Confirm who installs, connects, operates, inspects and removes; approval by one party does not replace the others.
Yamaha QL1: separate audio, remote control and public Wi-Fi
The specification identifies Yamaha QL1 operated over network and iPad, 4 d&b Yi7p and 2 d&b Bi6 fixed to the grid; monitoring lists 2 d&b E8 and a D-6 amplifier, with possible rental charges. The older plot labels EAW: confirm the installed system and patch before reusing settings or presets.
County public Wi-Fi does not establish access to the control network. Yamaha describes QL StageMix as remote control of QL series through an access point connected to the console. Obtain the authorized app, versions and network; do not change IP, DHCP, firmware or presets during the show to try to restore a connection.
| Check to perform with the operator | What the result helps distinguish |
|---|---|
| Known source, accepted input channel and output; moderate level | Input signal without output suggests routing or control; output signal without sound requires checking the downstream chain. |
| Compare control at QL1 and on the iPad | If the console responds but the app does not, review the control link before intervening in the audio chain. |
| Check each monitor and destination separately | Helps identify a crossed route or missing destination without changing the whole mix. |
Agree on the initial state with the operator and save the necessary files before changes. If a check worsens the result, remove the change and restore the accepted state. At completion, restore patch, lighting positions and audio configuration, remove additions and check inventory and floor. Also define who receives the room and the final plan revision.
Frequently asked questions
Does the Black Box accommodate 129 or 136 spectators?
The space page states 129 and the 17/07/2026 technical specification states 136. Submit the full plan and obtain the accepted capacity for that layout before issuing tickets. Neither number alone approves different stage, FOH or aisle arrangements.
If equipment fits the 10 ft × 12 ft dock, can it reach the room?
Not necessarily: the specification states a Black Box doorway 6 ft high × 6 ft wide. Confirm the entire route with packaging, wheels, turns and floor protection. If it does not fit, change package preparation or equipment before dispatch.
Does 200 lb/ft² authorize a motor or LED display on the grid?
It does not identify point capacity or residual load. Submit positions, weights, reactions and attachment method for prior Production approval and applicable structural review. Do not calculate points by multiplying area by this general figure.
Can I load the 2023 lighting plot patch directly into ETC Ion?
First reconcile fixtures, modes, addresses and universes with the operator: the 2026 specification and plot differ on COLORado and LoneStar. Keep the house file, check destinations in limited steps and restore accepted positions on completion. Do not include the run light in the design without confirmation.
Does free Wi-Fi let me control Yamaha QL1 from my iPad?
It does not establish control-network access or app compatibility. Obtain the authorized application, versions and connection from the operator. If QL1 responds locally but the iPad does not, check the control link first; do not reboot equipment or change the audio network on that observation alone.
Does haze appearing in the fee schedule mean I can use it?
The 23/01/2024 fee schedule is a rental and charge reference, not an effects permit. Submit model, manual and scope for acceptance by the venue and competent authority. Retain the version without the effect until those confirmations are obtained.